garage_decke: VL/RL-Anzeige folgt KD-Flussrichtung
Schalter tauscht hydraulische Zuordnung der fest montierten Fühler; ΔT bleibt Rücklauf minus Vorlauf.
This commit is contained in:
parent
92a5eca903
commit
5dd791aae0
1 changed files with 195 additions and 33 deletions
|
|
@ -9,7 +9,7 @@
|
|||
],
|
||||
"timezone": "browser",
|
||||
"schemaVersion": 39,
|
||||
"version": 3,
|
||||
"version": 4,
|
||||
"refresh": "30s",
|
||||
"panels": [
|
||||
{
|
||||
|
|
@ -77,9 +77,43 @@
|
|||
"uid": "ffptl25vzylfke"
|
||||
},
|
||||
"query": "SELECT last(\"value\") FROM \"temperature\" WHERE \"node\"='garage_decke' AND \"sensor\"='rl_klimadecke' AND $timeFilter",
|
||||
"rawQuery": true
|
||||
"rawQuery": true,
|
||||
"hide": true
|
||||
},
|
||||
{
|
||||
"refId": "B",
|
||||
"datasource": {
|
||||
"type": "influxdb",
|
||||
"uid": "ffptl25vzylfke"
|
||||
},
|
||||
"query": "SELECT last(\"value\") FROM \"temperature\" WHERE \"node\"='garage_decke' AND \"sensor\"='vl_kaeltedecke' AND $timeFilter",
|
||||
"rawQuery": true,
|
||||
"hide": true
|
||||
},
|
||||
{
|
||||
"refId": "RL",
|
||||
"datasource": {
|
||||
"type": "__expr__",
|
||||
"uid": "__expr__",
|
||||
"name": "Expression"
|
||||
},
|
||||
"type": "math",
|
||||
"expression": "($A + $B - ${kd_flussrichtung} * ($A - $B)) / 2",
|
||||
"hide": false
|
||||
},
|
||||
{
|
||||
"refId": "VL",
|
||||
"datasource": {
|
||||
"type": "__expr__",
|
||||
"uid": "__expr__",
|
||||
"name": "Expression"
|
||||
},
|
||||
"type": "math",
|
||||
"expression": "($A + $B + ${kd_flussrichtung} * ($A - $B)) / 2",
|
||||
"hide": true
|
||||
}
|
||||
]
|
||||
],
|
||||
"description": "Rücklauf Kältedecke (wärmer). Bei umgekehrter Flussrichtung wird der passende Rohr-Fühler per Schalter zugeordnet — Influx-Tags bleiben fix."
|
||||
},
|
||||
{
|
||||
"id": 2,
|
||||
|
|
@ -214,10 +248,44 @@
|
|||
"type": "influxdb",
|
||||
"uid": "ffptl25vzylfke"
|
||||
},
|
||||
"query": "SELECT last(\"value\") FROM \"temperature\" WHERE \"node\"='garage_decke' AND \"sensor\"='rl_klimadecke' AND $timeFilter",
|
||||
"rawQuery": true,
|
||||
"hide": true
|
||||
},
|
||||
{
|
||||
"refId": "B",
|
||||
"datasource": {
|
||||
"type": "influxdb",
|
||||
"uid": "ffptl25vzylfke"
|
||||
},
|
||||
"query": "SELECT last(\"value\") FROM \"temperature\" WHERE \"node\"='garage_decke' AND \"sensor\"='vl_kaeltedecke' AND $timeFilter",
|
||||
"rawQuery": true
|
||||
"rawQuery": true,
|
||||
"hide": true
|
||||
},
|
||||
{
|
||||
"refId": "RL",
|
||||
"datasource": {
|
||||
"type": "__expr__",
|
||||
"uid": "__expr__",
|
||||
"name": "Expression"
|
||||
},
|
||||
"type": "math",
|
||||
"expression": "($A + $B - ${kd_flussrichtung} * ($A - $B)) / 2",
|
||||
"hide": true
|
||||
},
|
||||
{
|
||||
"refId": "VL",
|
||||
"datasource": {
|
||||
"type": "__expr__",
|
||||
"uid": "__expr__",
|
||||
"name": "Expression"
|
||||
},
|
||||
"type": "math",
|
||||
"expression": "($A + $B + ${kd_flussrichtung} * ($A - $B)) / 2",
|
||||
"hide": false
|
||||
}
|
||||
]
|
||||
],
|
||||
"description": "Vorlauf Kältedecke (kälter). Zuordnung über KD Flussrichtung oben."
|
||||
},
|
||||
{
|
||||
"id": 4,
|
||||
|
|
@ -383,7 +451,33 @@
|
|||
"showPoints": "never",
|
||||
"axisPlacement": "auto"
|
||||
}
|
||||
}
|
||||
},
|
||||
"overrides": [
|
||||
{
|
||||
"matcher": {
|
||||
"id": "byFrameRefID",
|
||||
"options": "RL_KD"
|
||||
},
|
||||
"properties": [
|
||||
{
|
||||
"id": "displayName",
|
||||
"value": "RL Klimadecke"
|
||||
}
|
||||
]
|
||||
},
|
||||
{
|
||||
"matcher": {
|
||||
"id": "byFrameRefID",
|
||||
"options": "VL_KD"
|
||||
},
|
||||
"properties": [
|
||||
{
|
||||
"id": "displayName",
|
||||
"value": "VL Kältedecke"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"options": {
|
||||
"legend": {
|
||||
|
|
@ -403,13 +497,46 @@
|
|||
},
|
||||
"targets": [
|
||||
{
|
||||
"refId": "rl_klimadecke",
|
||||
"refId": "KD_A",
|
||||
"datasource": {
|
||||
"type": "influxdb",
|
||||
"uid": "ffptl25vzylfke"
|
||||
},
|
||||
"query": "SELECT mean(\"value\") AS \"RL Klimadecke\" FROM \"temperature\" WHERE \"node\"='garage_decke' AND \"sensor\"='rl_klimadecke' AND $timeFilter GROUP BY time($__interval)",
|
||||
"rawQuery": true
|
||||
"query": "SELECT mean(\"value\") FROM \"temperature\" WHERE \"node\"='garage_decke' AND \"sensor\"='rl_klimadecke' AND $timeFilter GROUP BY time($__interval)",
|
||||
"rawQuery": true,
|
||||
"hide": true
|
||||
},
|
||||
{
|
||||
"refId": "KD_B",
|
||||
"datasource": {
|
||||
"type": "influxdb",
|
||||
"uid": "ffptl25vzylfke"
|
||||
},
|
||||
"query": "SELECT mean(\"value\") FROM \"temperature\" WHERE \"node\"='garage_decke' AND \"sensor\"='vl_kaeltedecke' AND $timeFilter GROUP BY time($__interval)",
|
||||
"rawQuery": true,
|
||||
"hide": true
|
||||
},
|
||||
{
|
||||
"refId": "RL_KD",
|
||||
"datasource": {
|
||||
"type": "__expr__",
|
||||
"uid": "__expr__",
|
||||
"name": "Expression"
|
||||
},
|
||||
"type": "math",
|
||||
"expression": "($A + $B - ${kd_flussrichtung} * ($A - $B)) / 2",
|
||||
"hide": false
|
||||
},
|
||||
{
|
||||
"refId": "VL_KD",
|
||||
"datasource": {
|
||||
"type": "__expr__",
|
||||
"uid": "__expr__",
|
||||
"name": "Expression"
|
||||
},
|
||||
"type": "math",
|
||||
"expression": "($A + $B + ${kd_flussrichtung} * ($A - $B)) / 2",
|
||||
"hide": false
|
||||
},
|
||||
{
|
||||
"refId": "pwt",
|
||||
|
|
@ -420,15 +547,6 @@
|
|||
"query": "SELECT mean(\"value\") AS \"PWT-Oberfläche\" FROM \"temperature\" WHERE \"node\"='garage_decke' AND \"sensor\"='pwt' AND $timeFilter GROUP BY time($__interval)",
|
||||
"rawQuery": true
|
||||
},
|
||||
{
|
||||
"refId": "vl_kaeltedecke",
|
||||
"datasource": {
|
||||
"type": "influxdb",
|
||||
"uid": "ffptl25vzylfke"
|
||||
},
|
||||
"query": "SELECT mean(\"value\") AS \"VL Kältedecke\" FROM \"temperature\" WHERE \"node\"='garage_decke' AND \"sensor\"='vl_kaeltedecke' AND $timeFilter GROUP BY time($__interval)",
|
||||
"rawQuery": true
|
||||
},
|
||||
{
|
||||
"refId": "vl_brunnen",
|
||||
"datasource": {
|
||||
|
|
@ -453,7 +571,7 @@
|
|||
"id": 7,
|
||||
"type": "stat",
|
||||
"title": "ΔT Kältedecke",
|
||||
"description": "Wärmeaufnahme Kältedecke. Richtung über Variable „KD Flussrichtung“ oben: Normal = rl_klimadecke − vl_kaeltedecke, Umgekehrt = vl − rl (2. Pumpe).",
|
||||
"description": "Wärmeaufnahme Kältedecke = Rücklauf − Vorlauf (hydraulisch, unabhängig vom Flussrichtungs-Schalter).",
|
||||
"gridPos": {
|
||||
"h": 4,
|
||||
"w": 6,
|
||||
|
|
@ -510,7 +628,7 @@
|
|||
},
|
||||
"targets": [
|
||||
{
|
||||
"refId": "RL",
|
||||
"refId": "A",
|
||||
"datasource": {
|
||||
"type": "influxdb",
|
||||
"uid": "ffptl25vzylfke"
|
||||
|
|
@ -520,7 +638,7 @@
|
|||
"hide": true
|
||||
},
|
||||
{
|
||||
"refId": "VL",
|
||||
"refId": "B",
|
||||
"datasource": {
|
||||
"type": "influxdb",
|
||||
"uid": "ffptl25vzylfke"
|
||||
|
|
@ -529,6 +647,28 @@
|
|||
"rawQuery": true,
|
||||
"hide": true
|
||||
},
|
||||
{
|
||||
"refId": "RL",
|
||||
"datasource": {
|
||||
"type": "__expr__",
|
||||
"uid": "__expr__",
|
||||
"name": "Expression"
|
||||
},
|
||||
"type": "math",
|
||||
"expression": "($A + $B - ${kd_flussrichtung} * ($A - $B)) / 2",
|
||||
"hide": true
|
||||
},
|
||||
{
|
||||
"refId": "VL",
|
||||
"datasource": {
|
||||
"type": "__expr__",
|
||||
"uid": "__expr__",
|
||||
"name": "Expression"
|
||||
},
|
||||
"type": "math",
|
||||
"expression": "($A + $B + ${kd_flussrichtung} * ($A - $B)) / 2",
|
||||
"hide": true
|
||||
},
|
||||
{
|
||||
"refId": "DT",
|
||||
"datasource": {
|
||||
|
|
@ -537,7 +677,7 @@
|
|||
"name": "Expression"
|
||||
},
|
||||
"type": "math",
|
||||
"expression": "${kd_flussrichtung} * ($RL - $VL)",
|
||||
"expression": "$RL - $VL",
|
||||
"hide": false
|
||||
}
|
||||
]
|
||||
|
|
@ -932,23 +1072,45 @@
|
|||
},
|
||||
"targets": [
|
||||
{
|
||||
"refId": "RL_KD",
|
||||
"refId": "KD_A",
|
||||
"datasource": {
|
||||
"type": "influxdb",
|
||||
"uid": "ffptl25vzylfke"
|
||||
},
|
||||
"query": "SELECT mean(\"value\") AS \"RL KD\" FROM \"temperature\" WHERE \"node\"='garage_decke' AND \"sensor\"='rl_klimadecke' AND $timeFilter GROUP BY time($__interval)",
|
||||
"query": "SELECT mean(\"value\") FROM \"temperature\" WHERE \"node\"='garage_decke' AND \"sensor\"='rl_klimadecke' AND $timeFilter GROUP BY time($__interval)",
|
||||
"rawQuery": true,
|
||||
"hide": true
|
||||
},
|
||||
{
|
||||
"refId": "KD_B",
|
||||
"datasource": {
|
||||
"type": "influxdb",
|
||||
"uid": "ffptl25vzylfke"
|
||||
},
|
||||
"query": "SELECT mean(\"value\") FROM \"temperature\" WHERE \"node\"='garage_decke' AND \"sensor\"='vl_kaeltedecke' AND $timeFilter GROUP BY time($__interval)",
|
||||
"rawQuery": true,
|
||||
"hide": true
|
||||
},
|
||||
{
|
||||
"refId": "RL_KD",
|
||||
"datasource": {
|
||||
"type": "__expr__",
|
||||
"uid": "__expr__",
|
||||
"name": "Expression"
|
||||
},
|
||||
"type": "math",
|
||||
"expression": "($A + $B - ${kd_flussrichtung} * ($A - $B)) / 2",
|
||||
"hide": true
|
||||
},
|
||||
{
|
||||
"refId": "VL_KD",
|
||||
"datasource": {
|
||||
"type": "influxdb",
|
||||
"uid": "ffptl25vzylfke"
|
||||
"type": "__expr__",
|
||||
"uid": "__expr__",
|
||||
"name": "Expression"
|
||||
},
|
||||
"query": "SELECT mean(\"value\") AS \"VL KD\" FROM \"temperature\" WHERE \"node\"='garage_decke' AND \"sensor\"='vl_kaeltedecke' AND $timeFilter GROUP BY time($__interval)",
|
||||
"rawQuery": true,
|
||||
"type": "math",
|
||||
"expression": "($A + $B + ${kd_flussrichtung} * ($A - $B)) / 2",
|
||||
"hide": true
|
||||
},
|
||||
{
|
||||
|
|
@ -959,7 +1121,7 @@
|
|||
"name": "Expression"
|
||||
},
|
||||
"type": "math",
|
||||
"expression": "${kd_flussrichtung} * ($RL_KD - $VL_KD)",
|
||||
"expression": "$RL_KD - $VL_KD",
|
||||
"hide": false
|
||||
},
|
||||
{
|
||||
|
|
@ -1016,10 +1178,10 @@
|
|||
{
|
||||
"current": {
|
||||
"selected": true,
|
||||
"text": "Umgekehrt (VL−RL)",
|
||||
"text": "Umgekehrt (Fühler getauscht)",
|
||||
"value": "-1"
|
||||
},
|
||||
"description": "Flussrichtung Kältedecke: Sensor-Tags rl_klimadecke/vl_kaeltedecke bleiben am Rohr, ΔT wird mit Faktor 1 (RL−VL) oder −1 (VL−RL) berechnet. Stand 27.06.: umgekehrt (2. Pumpe, Entlüftung).",
|
||||
"description": "Flussrichtung Kältedecke: tauscht hydraulische VL/RL-Zuordnung der fest montierten Fühler (rl_klimadecke, vl_kaeltedecke). Normal = Standard; Umgekehrt = 2. Pumpe / Entlüftung.",
|
||||
"hide": 0,
|
||||
"includeAll": false,
|
||||
"label": "KD Flussrichtung",
|
||||
|
|
@ -1028,12 +1190,12 @@
|
|||
"options": [
|
||||
{
|
||||
"selected": false,
|
||||
"text": "Normal (RL−VL)",
|
||||
"text": "Normal (Fühler = VL/RL)",
|
||||
"value": "1"
|
||||
},
|
||||
{
|
||||
"selected": true,
|
||||
"text": "Umgekehrt (VL−RL)",
|
||||
"text": "Umgekehrt (Fühler getauscht)",
|
||||
"value": "-1"
|
||||
}
|
||||
],
|
||||
|
|
|
|||
Loading…
Add table
Reference in a new issue